저주파 변압기 성능 테스트

작가: 맥탑
2022-07-08
연구 배경
적절한 차폐 설치 저주파 변압기 can effectively suppress interference and improve electromagnetic compatibility of the system. Shielding efficiency is an important index to measure shielding performance. According to the calculation formula of shielding efficiency, magnetic field tester is usually used to test the magnetic field intensity or electric field intensity before and after shielding. The direct purchase of magnetic field tester is seriously restricted by the performance and price ratio. Therefore, in view of the nature and characteristics of the transformer, a 저주파 변압기 shielding efficiency test system is established. The shielding efficiency of 50 VA power frequency E transformer under three shielding modes is tested by indirect method. The results show that the performance and price ratio of the shielding efficiency test system is high, the test results are accurate and reliable, and meet the requirements of electromagnetic compatibility, which provides a decision basis for choosing the appropriate shielding form and anti-jamming measures.

Composition and testing principle of 저주파 변압기 shielding testing system
시스템은 자체 제작한 테스트 랙(프로브 및
턴테이블), 동축 케이블과 트랜지스터 밀리볼트 미터를 연결합니다.
차폐 효과는 간접적으로 측정되었습니다.
측정. 기본 원리는 수제 프로브 센서입니다.
필드의 공간 예약 지점(코일), 프로브 테스트 코일을 통한 수직 자기장 라인, a에 의한 유도 신호
동축 케이블 전송, 유도 전압 RMS 밀리볼트미터
맥스웰의 방정식에 따라 트랜지스터에 의해 측정된
자기유도강도와 자기장강도, 자속과 자기유도강도의 관계
관계식 유도 전위가 유도된다.
정현파 자기장에서 차폐 효율은 다음과 같습니다.
유도 전위(U0, U1)의 비율로 측정
차폐 전후 공간의 한 지점. 차폐 효율은 일반적으로 데시벨(DB)로 표시됩니다.




연구 결론
이중층 차폐의 차폐 효율은 그보다 우수합니다.
단층 실드, 단층 실드 효율
실드는 단락 링보다 우수합니다. 이중 차폐
차폐 차폐 효과의 차폐 효과는 하나의 단순한 합이 아니라 처음으로 측정되는 변압기에서 누설 자기장을 기반으로 낮은 자기 저항 경로를 제공하고 다시 첫 번째 레이어를 통해
낮은 자기저항의 자속누설 차폐
두 번째 레이어 차폐로 경로, 그래서 비교
단일 레이어 차폐, 이중 레이어 차폐 외부 누출
자기장이 크게 감소했습니다. 단락 링 차폐는 자기 누설 필드를 사용하여 회로에 와전류를 생성합니다.
좋은 도체의 단락 회로 링, 차례로 생성
그 효과를 상쇄하기 위해 자기 누설 필드에 반대되는 자기장. 이 구조의 차폐 효율이 증가합니다.
자기 누설 필드의 주파수의 증가와
유도 와전류의 증가 및 와전류의 차폐 효과는 저주파에서 분명하지 않습니다. 이 결과는
전자기 이론과의 좋은 일치.