Quelle pourrait être la cause de l'épuisement du transformateur de commande ?

2022-09-08
image

Dans l'industrie des machines d'aujourd'hui, presque toutes les machines-outils nécessitent un transformateur de commande. The role of the transformateur de commande is often used as the local lighting power supply, signal lamp or indicator power supply for machinery and equipment, and can also be used as the control circuit power supply in electrical equipment. However, when using the transformateur de commande, many people may encounter the problem of the transformateur de commande being burnt out. In general, what causes the transformateur de commande to burn out?

(1) The overloaded use of the transformateur de commande transformer causes the temperature rise to be too large, which has exceeded the temperature resistance level of the insulating material, thereby burning the transformer.

(2) L'isolation entre les spires des bobines primaire et secondaire est endommagée ou vieillie, il y a un court-circuit entre les spires et une surchauffe locale entraîne un grillage.

(3) La partie de soudage du fil de sortie est un soudage virtuel et la résistance de contact est élevée, ce qui entraîne une densité de courant locale élevée et même le fil peut être fusionné.

(4) Si le noyau de fer a des boulons traversants, les boulons doivent être isolés d'au moins un côté du noyau de fer. Sinon, si un court-circuit magnétique se produit, les boulons seront brûlés en rouge.

The above 4 points are the main reasons why the transformateur de commande is prone to burn out! After we understand these 4 factors, when we need to use the transformateur de commande, we can avoid the transformateur de commande with a little attention. burnt condition.

Response measures to transformateur de commande burnout:
transformateur de commande
(1) For the transformateur de commande to be burned out due to overload, it is required to replace a transformateur de commande with a larger capacity. The power rating of the applied transformateur de commande must be greater than that of the driven appliance.

(2) The cause of the circuit failure causes the short circuit of the low-voltage control circuit, which makes the secondary coil current of the transformateur de commande too large, which exceeds the rated current of the transformer and burns the machine tool transformateur de commande. In this regard, the current limit insurance can be added in front of the transformer for protection.

(3) It is usually necessary to check the insulation of the line. When the insulation of the transformateur de commande is found to be damaged or aged, the transformer should be replaced in time to avoid leakage and short circuit.

(4) Vérifiez s'il y a un blocage dans la partie rotative de la machine pour éviter les surintensités.