Kontrol transformatörünün yanmasının nedeni ne olabilir?

2022-09-08
image

Günümüzün makine endüstrisinde, hemen hemen her takım tezgahı bir kontrol transformatörü. The role of the kontrol transformatörü is often used as the local lighting power supply, signal lamp or indicator power supply for machinery and equipment, and can also be used as the control circuit power supply in electrical equipment. However, when using the kontrol transformatörü, many people may encounter the problem of the kontrol transformatörü being burnt out. In general, what causes the kontrol transformatörü to burn out?

(1) The overloaded use of the kontrol transformatörü transformer causes the temperature rise to be too large, which has exceeded the temperature resistance level of the insulating material, thereby burning the transformer.

(2) Birincil ve ikincil bobinlerin dönüşler arası yalıtımı hasar görmüş veya eskimiş, dönüşler arasında kısa devre var ve yerel aşırı ısınma yanmaya neden oluyor.

(3) Çıkış telinin kaynak kısmı sanal kaynaktır ve temas direnci büyüktür, bu da yüksek yerel akım yoğunluğuna neden olur ve hatta tel kaynaştırılabilir.

(4) Demir göbeğin delikli cıvataları varsa, cıvatalar demir göbeğe en az bir taraftan yalıtılmalıdır. Aksi takdirde, bir manyetik kısa devreye neden olursa, cıvatalar kırmızı renkte yanacaktır.

The above 4 points are the main reasons why the kontrol transformatörü is prone to burn out! After we understand these 4 factors, when we need to use the kontrol transformatörü, we can avoid the kontrol transformatörü with a little attention. burnt condition.

Response measures to kontrol transformatörü burnout:
kontrol transformatörü
(1) For the kontrol transformatörü to be burned out due to overload, it is required to replace a kontrol transformatörü with a larger capacity. The power rating of the applied kontrol transformatörü must be greater than that of the driven appliance.

(2) The cause of the circuit failure causes the short circuit of the low-voltage control circuit, which makes the secondary coil current of the kontrol transformatörü too large, which exceeds the rated current of the transformer and burns the machine tool kontrol transformatörü. In this regard, the current limit insurance can be added in front of the transformer for protection.

(3) It is usually necessary to check the insulation of the line. When the insulation of the kontrol transformatörü is found to be damaged or aged, the transformer should be replaced in time to avoid leakage and short circuit.

(4) Aşırı akımı önlemek için makinenin dönen kısmında sıkışma olup olmadığını kontrol edin.