Leakage inductance of the primary coil - the leakage inductance of the transformer is caused by the incomplete coupling of the magnetic flux between the primary coil and the secondary coil, between layers, and between turns.
Distributed capacitance - The capacitance formed between the turns of the transformer winding, between the upper and lower layers of the same winding, between different windings, and between the winding and the shielding layer is called distributed capacitance.
Primary winding ---- The primary winding should be placed in
Secondary winding - after the primary winding is wound, (3 to 5) layers of insulating padding need to be wound and then the secondary winding is wound. This can reduce the capacitance of the distributed capacitance between the primary winding and the secondary winding, and also increase the insulation strength between the primary and secondary windings, meeting the requirements of insulation withstand voltage.
Bias winding - Whether the bias winding is wound between the primary and secondary, or on the outermost layer, is related to whether the switching power supply is adjusted based on the secondary voltage or the primary voltage.